{"product_id":"atlas®-edge-long-calibration-bar-rav-ateatedge-stda14","title":"Atlas® Edge Long Calibration Bar (RAV) #ATEATEDGE-STDA14","description":"\u003cdiv class=\"product-quick-specs\" style=\"background: #f5f5f5; border-radius: 5px; padding: 16px 20px; margin: 0 0 16px 0; font-family: Roboto,sans-serif;\" role=\"region\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #283c92; font-size: 16px; margin: 0 0 8px 0; border-bottom: 2px solid #283c92; padding: 0 0 6px 0;\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"product-tablewrap\" style=\"overflow-x: auto; margin: 0; padding: 0;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border-spacing: 0; font-size: 14px; margin: 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 7px 12px; font-weight: 600; color: #283c92; width: 45%;\"\u003eAtlas SKU\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 12px;\"\u003eATEATEDGE-STDA14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #eef0f9;\"\u003e\n\u003ctd style=\"padding: 7px 12px; font-weight: 600; color: #283c92;\"\u003eRavaglioli Reference\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 12px;\"\u003eSTDA14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 7px 12px; font-weight: 600; color: #283c92;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 12px;\"\u003eLong Calibration Bar \/ Standard Calibration Tool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #eef0f9;\"\u003e\n\u003ctd style=\"padding: 7px 12px; font-weight: 600; color: #283c92;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 12px;\"\u003eAlignment Sensor \/ Detector Calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 7px 12px; font-weight: 600; color: #283c92;\"\u003eDocumented Atlas Applications\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 12px;\"\u003eEdge 501 \/ 601 Pro with Firmware 4.0+; Edge 801 Truck Aligner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #eef0f9;\"\u003e\n\u003ctd style=\"padding: 7px 12px; font-weight: 600; color: #283c92;\"\u003eCurrent Ravaglioli Replacement Note\u003c\/td\u003e\n\u003ctd style=\"padding: 7px 12px;\"\u003eSTDA163 Replaces STDA14 for WS \/ WD Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-description\" style=\"font-family: Roboto,sans-serif; color: #333; max-width: 900px;\"\u003e\n\u003ch2 style=\"color: #283c92; font-size: 18px; margin: 0 0 10px 0;\"\u003eAtlas Edge STDA14 Long Calibration Bar for Alignment Systems #ATEATEDGE-STDA14\u003c\/h2\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.7;\"\u003eAtlas Edge #ATEATEDGE-STDA14 is the Ravaglioli STDA14 standard calibration tool used for calibration procedures on compatible CCD wheel-alignment sensor heads. Ravaglioli service documentation identifies STDA14 as a detector-calibration system used when calibration is required after certain sensor or transducer service conditions.\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.7;\"\u003eAtlas dealer documentation identifies the STDA14 long calibration bar for Edge 501 and 601 Pro systems with firmware 4.0 and above, as well as the Edge 801 truck alignment system. Confirm the exact aligner generation and software\/firmware before ordering.\u003c\/p\u003e\n\u003ch3 style=\"color: #283c92; font-size: 15px; border-bottom: 2px solid #283c92; padding-bottom: 6px;\"\u003eCompatibility \u0026amp; Fitment\u003c\/h3\u003e\n\u003cdiv class=\"compatibility-tablewrap\" style=\"overflow-x: auto; margin: 0; padding: 0;\"\u003e\n\u003ctable class=\"compatibility-table\" style=\"width: 100%; border-collapse: collapse; border-spacing: 0; font-size: 14px; margin: 0;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #283c92; color: #fff;\"\u003e\n\u003cth style=\"padding: 8px 12px; text-align: left;\"\u003eAlignment System\u003c\/th\u003e\n\u003cth style=\"padding: 8px 12px; text-align: left;\"\u003eCompatibility Note\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 8px 12px;\"\u003eAtlas Edge 501\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px;\"\u003eDealer documentation specifies firmware 4.0 and above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #eef0f9;\"\u003e\n\u003ctd style=\"padding: 8px 12px;\"\u003eAtlas Edge 601 Pro\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px;\"\u003eDealer documentation specifies firmware 4.0 and above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 8px 12px;\"\u003eAtlas Edge 801 Truck Aligner\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px;\"\u003eDocumented STDA14 application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #eef0f9;\"\u003e\n\u003ctd style=\"padding: 8px 12px;\"\u003eRavaglioli WS \/ WD Series\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 12px;\"\u003eCurrent Ravaglioli STDA163 replaces STDA14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"color: #283c92; font-size: 15px; border-bottom: 2px solid #283c92; padding-bottom: 6px;\"\u003eCalibration Use\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.7;\"\u003eRavaglioli states that measuring heads are factory calibrated and store their calibration values internally. Calibration is generally performed when transducers are replaced or when repeated measurement errors indicate that sensor components may have shifted following impact or similar service events.\u003c\/p\u003e\n\u003cdiv style=\"background: #fff4e5; border: 2px solid #cc7a00; border-radius: 5px; padding: 14px 18px; margin: 18px 0; font-size: 14px; line-height: 1.6;\"\u003e\n\u003cstrong style=\"color: #cc7a00;\"\u003e⚠ Check your aligner generation:\u003c\/strong\u003e STDA14 is not the current calibration tool for every Ravaglioli alignment platform. Ravaglioli now lists STDA163 as the replacement for STDA14 on WS and WD series systems.\u003c\/div\u003e\n\u003cdiv class=\"product-faq\" role=\"region\"\u003e\n\u003ch3 style=\"color: #283c92; font-size: 16px; border-bottom: 2px solid #283c92; padding-bottom: 6px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdiv style=\"border: 1px solid #e0e0e0; border-radius: 5px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003ch3 style=\"background: #eef0f9; color: #283c92; margin: 0; padding: 14px 18px; font-size: 15px;\"\u003eWhat is the STDA14 used for?\u003c\/h3\u003e\n\u003cp style=\"padding: 14px 18px; margin: 0; font-size: 14px; line-height: 1.7; color: #333;\"\u003eSTDA14 is a calibration fixture used for compatible wheel-alignment detector or sensor-head calibration procedures.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #e0e0e0; border-radius: 5px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003ch3 style=\"background: #eef0f9; color: #283c92; margin: 0; padding: 14px 18px; font-size: 15px;\"\u003eDoes every replacement sensor head need calibration?\u003c\/h3\u003e\n\u003cp style=\"padding: 14px 18px; margin: 0; font-size: 14px; line-height: 1.7; color: #333;\"\u003eNot necessarily. Ravaglioli documentation states that detector calibration values are stored in the detector itself and calibration is generally required only under specified service conditions such as transducer replacement or confirmed repeated measurement errors.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #e0e0e0; border-radius: 5px; margin-bottom: 10px; overflow: hidden;\"\u003e\n\u003ch3 style=\"background: #eef0f9; color: #283c92; margin: 0; padding: 14px 18px; font-size: 15px;\"\u003eIs STDA14 still the current calibration tool for every Ravaglioli aligner?\u003c\/h3\u003e\n\u003cp style=\"padding: 14px 18px; margin: 0; font-size: 14px; line-height: 1.7; color: #333;\"\u003eNo. Ravaglioli currently identifies STDA163 as the replacement for STDA14 on WS and WD series alignment systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #eef0f9; border-radius: 5px; padding: 16px 20px; margin: 16px 0;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px;\"\u003eQuestions before ordering? Call \u003ca href=\"tel:+18178653707\" style=\"color: #283c92; font-weight: 600;\"\u003e(817) 865-3707\u003c\/a\u003e with your Atlas Edge model and firmware version so we can help confirm the correct calibration fixture.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\n.product-quick-specs .product-tablewrap,\n.product-quick-specs .table-wrapper,\n.product-quick-specs table,\n.product-quick-specs tbody,\n.product-quick-specs tr{\nmargin:0!important;\npadding:0!important;\nheight:auto!important;\n}\n.product-quick-specs{\npadding:16px 20px!important;\n}\n.product-quick-specs table td,\n.product-quick-specs table th{\npadding:7px 12px!important;\nline-height:1.35!important;\nheight:auto!important;\nvertical-align:middle!important;\n}\n.product-description .compatibility-tablewrap,\n.product-description .compatibility-tablewrap .table-wrapper,\n.product-description .compatibility-table,\n.product-description .compatibility-table thead,\n.product-description .compatibility-table tbody,\n.product-description .compatibility-table tr{\nmargin:0!important;\npadding:0!important;\nheight:auto!important;\n}\n.product-description .compatibility-table td,\n.product-description .compatibility-table th{\npadding:8px 12px!important;\nline-height:1.35!important;\nheight:auto!important;\nvertical-align:middle!important;\n}\n\u003c\/style\u003e","brand":"Atlas® Automotive Equipment","offers":[{"title":"Default Title","offer_id":53845504295205,"sku":"ALMATLATEATEDGESTDA14","price":5499.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0758\/0037\/9685\/files\/Atlas_ATEATEDGE-STDA14.jpg?v=1790054520","url":"https:\/\/alamoequipment.com\/products\/atlas%c2%ae-edge-long-calibration-bar-rav-ateatedge-stda14","provider":"Alamo Equipment","version":"1.0","type":"link"}