| Model / Part Number | FRNB00100-1XA5XX |
| Capacity | 100 SCFM |
| Connections | 1" NPT |
| Voltage | 460/3/60 (575/3/60 optional) |
| Max Operating Pressure | 232 psig |
| Warranty | 2-year |
FS-Curtis RNB100 — 100 SCFM Refrigerated Air Dryer
A commercial shop running several bays off one central compressor needs dew point control that doesn't waver when demand spikes — the RNB100 is sized for that kind of steady, higher-volume commercial use.
That's what the FS-Curtis RNB100 solves — a 100 SCFM non-cycling refrigerated dryer, a dependable way to keep the air line dry without adding a piece of equipment that needs its own babysitting. It's also available with a factory-matched Filter Package (prefilter CF7-24-8-DGL + afterfilter CF5-24-8-DGL) as an add-on option, which puts factory-correct filtration inline from day one, instead of adding it as an afterthought once a moisture problem shows up.
Who the RNB100 Is Built For
- âś… A multi-bay shop running a mid-size rotary screw compressor (typically 15-30 HP) where several techs pull air from the same line throughout the day
- âś… A shop that already has 3-phase power in place and wants a dryer sized to actually match the compressor's real output, instead of undersizing and choking the system
- âś… An operation that needs consistent dew point control across a full 8-10 hour shift, not just intermittent weekend-warrior use
- âś… A shop that's grown out of a smaller single-phase dryer and is tired of it cycling or falling behind once two or three bays are running air tools simultaneously
- ✅ A facility running sensitive downstream equipment — spray booths, sandblast cabinets, precision pneumatic tools — where wet air causes real, expensive problems
What the RNB100 Is NOT Built For
- ❌ Small single-bay shops with light, intermittent air demand — a smaller RNB model in the 115V tier saves real upfront cost
- ❌ Very high-volume industrial operations that exceed this unit's rated SCFM — check the 200+ SCFM models instead so the dryer isn't the bottleneck
What Makes the RNB100 Different
Heat Exchanger
The RNB100 uses a stainless steel brazed plate heat exchanger, engineered for reliable, consistent dew point control at 100 SCFM without fouling or excess pressure drop.
Condensate Drain
Timed electric drain removes collected moisture automatically — it discharges on its own schedule, freeing your team from tracking one more manual step.
Refrigerant & Air Quality
Uses R513A refrigerant, a low global-warming-potential option, and delivers ISO 8573-1:2010 Class 4–5 pressure dew point — dry, reliable air for general shop and industrial use.
Optional Filter Package
Choose the “Includes Filter Package” option to add a factory-matched prefilter (CF7-24-8-DGL) and afterfilter (CF5-24-8-DGL), sized to this dryer's flow rate and ready to plumb — one less step for your install crew.
- Multi-bay / light industrial shops
- Mid-size rotary screw or piston compressors
- Steady all-day air demand
- Small single-bay shops
- High-volume industrial lines
RNB100 vs. FS-Curtis RNB125 (125 SCFM) — Which Dryer Is Right for Your Shop?
| Decision Point | RNB100 | FS-Curtis RNB125 (125 SCFM) |
|---|---|---|
| Capacity (SCFM) | 100 SCFM | 125 SCFM |
| Price | $3,307 | $3,709 |
| Voltage | 460/3/60 (575/3/60 optional) | 460/3/60 (575/3/60 optional) |
| Connections | 1" NPT | 1" NPT |
Choose the RNB100 if your compressor's output matches 100 SCFM. Choose the RNB125 if you need more capacity headroom. Both stay inside Alamo’s catalog — call (844) 480-6059.
Full Specifications — RNB100
| Model / Part Number | FRNB00100-1XA5XX |
| Capacity | 100 SCFM |
| Voltage | 460/3/60 (575/3/60 optional) |
| Connections (In/Out) | 1" NPT |
| Heat Exchanger | Stainless steel brazed plate heat exchanger |
| Condensate Drain | Timed electric drain |
| Refrigerant | R513A (low global warming potential) |
| Max Inlet Temperature | 120°F (49°C) |
| Max Operating Pressure | 232 psig |
| Air Quality Standard | ISO 8573-1:2010, Class 4–5 pressure dew point |
| Filter Package Option | Available with prefilter CF7-24-8-DGL + afterfilter CF5-24-8-DGL — select “Includes Filter Package” above |
| Overall Dimensions (L x W x D) | 19.3" L x 37.2" W x 32.3" D |
| Shipping Weight | 129 lbs |
| Warranty | 2-year |
⚠️ Setup Requirements
- Electrical: 460/3/60 (575/3/60 optional); have an electrician confirm your panel capacity before delivery.
- Floor space: 19.3" L x 37.2" W x 32.3" D footprint; plan clear access on at least one side for filter and drain maintenance.
- Piping: 1" NPT connections; install in-line after your compressor’s receiver tank, ahead of point-of-use air tools.
- Condensate drain: Timed electric drain — route the drain line to an approved oil/water separator or disposal point per local code.
- Weight: 129 lbs shipping weight — confirm your floor/dock can receive and position the unit.
- Setup: Installation is available as a quoted service (piping tie-in, drain routing, startup check) — it’s not included in the purchase price. Call (844) 480-6059 for an install quote if you’d like Alamo’s crew to set it up.
FS-Curtis Warranty — RNB100
FS-Curtis backs the RNB100 with a 2-year parts & labor warranty.
| Component | Coverage Term |
|---|---|
| Refrigeration circuit & heat exchanger | 2-year parts & labor |
| Condensate drain & controls | 2-year parts & labor |
| Filter package (if selected — prefilter/afterfilter) | 2-year parts & labor |
| Filter elements (consumable) | Not covered (consumable — replace per maintenance kit schedule) |
Warranty service is through Alamo Equipment & Service — call (844) 480-6059 instead of waiting on a manufacturer hotline. Coverage is subject to FS-Curtis warranty terms, conditions, and requirements.
Frequently Asked Questions — FS-Curtis RNB100
Why Buy the RNB100 from Alamo Equipment & Service?
- Installation available. Buying online gets you the dryer — piping tie-in and drain routing are an extra-charge service. We have the crews to install it and can quote that separately; call (844) 480-6059 for a quote.
- We service it. Refrigerated dryers need periodic filter and drain maintenance to keep dew point performance on spec. Call (844) 480-6059 for maintenance, repairs, or support — and if you ever need warranty work, we register your equipment with the manufacturer and handle the claim directly, so you’re not stuck navigating vendor support on your own.
- We size it with you. 100 SCFM at 232 psig — we’ll confirm this matches your compressor’s actual output and your shop’s air draw before you order.
- Free shipping. Ships free to the 48 contiguous states.
- Expert comparison help. Not sure if the RNB100 or the FS-Curtis RNB125 (125 SCFM) is the better fit? We’ll walk you through it.
A shop buying from a pure e-commerce retailer gets a box. A shop buying from Alamo gets a partner.
Shipping Rates and Delivery Estimates: Shipping is FREE to the 48 contiguous United States.
Shipment Processing Time: All orders are processed within [2–3] business days of receipt, excluding weekends and holidays. Orders are not processed or shipped from Friday at 12 pm CST through Sunday or on holidays. During periods of high order volume, shipments may be delayed by a few days. Customers will be notified via email or phone in the event of significant delays.
See the attached document for FS CURTIS WARRANTY