FS-Curtis RNB400 Non-Cycling Refrigerated Dryer 400 SCFM #FRNBX00400-4XA5XX
Couldn't load pickup availability
| Model / Part Number | FRNBX00400-4XA5XX |
| Capacity | 400 SCFM |
| Connections | 2" NPT |
| Voltage | 460/3/60 (575/3/60 optional) |
| Max Operating Pressure | 232 psig |
| Warranty | 2-year |
FS-Curtis RNB400 — 400 SCFM Refrigerated Air Dryer
A plant running a large rotary screw compressor around the 75-100 HP range needs matched drying capacity, not a smaller unit working past its limit — the RNB400 is sized specifically for that output range.
That's what the FS-Curtis RNB400 solves — a 400 SCFM non-cycling refrigerated dryer, built for shops that want dependable dew point control without paying for features this air volume doesn't call for. It's also available with a factory-matched Filter Package (prefilter CF7-40-16-DG + afterfilter CF5-40-16-DG) as an add-on option, which means the dryer and its filtration ship as one order, one delivery, and one part number to track instead of three.
Who the RNB400 Is Built For
- âś… An industrial facility or large commercial shop running a high-output rotary screw compressor that needs matched, continuous-duty drying capacity
- âś… An operation with a centralized compressed air system feeding multiple work areas, production lines, or bays from one header
- âś… A facility that needs dependable, round-the-clock dew point control at high SCFM without the pressure drop that undersized filtration or dryers introduce
- âś… A plant manager replacing an aging industrial dryer who needs the new unit to match or exceed the old one's throughput without a costly re-pipe of existing 2-inch/3-inch/4-inch flanged connections
- âś… An operation where compressed air system downtime for dryer service is expensive, making reliability and manufacturer-backed 2-year coverage a real purchasing factor, not an afterthought
What the RNB400 Is NOT Built For
- ❌ Small or mid-size shops — this tier is sized for industrial-volume air systems and is oversized, and overpriced, for a single-bay or light commercial operation
- ❌ Facilities without existing 3-phase power infrastructure or the floor space and flanged/NPT piping this unit's footprint and connections require
What Makes the RNB400 Different
Heat Exchanger
The RNB400 uses a stainless steel brazed plate heat exchanger, engineered for reliable, consistent dew point control at 400 SCFM without fouling or excess pressure drop.
Condensate Drain
Timed electric drain removes collected moisture automatically — moisture gets cleared out on a fixed schedule, with zero day-to-day attention from your crew.
Refrigerant & Air Quality
Uses R513A refrigerant, a low global-warming-potential option, and delivers ISO 8573-1:2010 Class 4–5 pressure dew point — dry, reliable air for general shop and industrial use.
Optional Filter Package
Choose the “Includes Filter Package” option to add a factory-matched prefilter (CF7-40-16-DG) and afterfilter (CF5-40-16-DG), sized to this dryer's flow rate and ready to plumb — one less step for your install crew.
- Industrial / high-volume facilities
- Centralized compressed air systems
- Continuous high-SCFM operation
- Small or mid-size shops
- Facilities without 3-phase power
RNB400 vs. FS-Curtis RNB500 (500 SCFM) — Which Dryer Is Right for Your Shop?
| Decision Point | RNB400 | FS-Curtis RNB500 (500 SCFM) |
|---|---|---|
| Capacity (SCFM) | 400 SCFM | 500 SCFM |
| Price | $8,828 | $9,999 |
| Voltage | 460/3/60 (575/3/60 optional) | 460/3/60 (575/3/60 optional) |
| Connections | 2" NPT | 2" NPT |
Choose the RNB400 if your compressor's output matches 400 SCFM. Choose the RNB500 if you need more capacity headroom. Both stay inside Alamo’s catalog — call (844) 480-6059.
Full Specifications — RNB400
| Model / Part Number | FRNBX00400-4XA5XX |
| Capacity | 400 SCFM |
| Voltage | 460/3/60 (575/3/60 optional) |
| Connections (In/Out) | 2" NPT |
| Heat Exchanger | Stainless steel brazed plate heat exchanger |
| Condensate Drain | Timed electric drain |
| Refrigerant | R513A (low global warming potential) |
| Max Inlet Temperature | 120°F (49°C) |
| Max Operating Pressure | 232 psig |
| Air Quality Standard | ISO 8573-1:2010, Class 4–5 pressure dew point |
| Filter Package Option | Available with prefilter CF7-40-16-DG + afterfilter CF5-40-16-DG — select “Includes Filter Package” above |
| Overall Dimensions (L x W x D) | 24.4" L x 48.7" W x 38.2" D |
| Shipping Weight | 279 lbs |
| Warranty | 2-year |
⚠️ Setup Requirements
- Electrical: 460/3/60 (575/3/60 optional); have an electrician confirm your panel capacity before delivery.
- Floor space: 24.4" L x 48.7" W x 38.2" D footprint; plan clear access on at least one side for filter and drain maintenance.
- Piping: 2" NPT connections; install in-line after your compressor’s receiver tank, ahead of point-of-use air tools.
- Condensate drain: Timed electric drain — route the drain line to an approved oil/water separator or disposal point per local code.
- Weight: 279 lbs shipping weight — confirm your floor/dock can receive and position the unit.
- Setup: Installation is available as a quoted service (piping tie-in, drain routing, startup check) — it’s not included in the purchase price. Call (844) 480-6059 for an install quote if you’d like Alamo’s crew to set it up.
FS-Curtis Warranty — RNB400
FS-Curtis backs the RNB400 with a 2-year parts & labor warranty.
| Component | Coverage Term |
|---|---|
| Refrigeration circuit & heat exchanger | 2-year parts & labor |
| Condensate drain & controls | 2-year parts & labor |
| Filter package (if selected — prefilter/afterfilter) | 2-year parts & labor |
| Filter elements (consumable) | Not covered (consumable — replace per maintenance kit schedule) |
Warranty service is through Alamo Equipment & Service — call (844) 480-6059 instead of waiting on a manufacturer hotline. Coverage is subject to FS-Curtis warranty terms, conditions, and requirements.
Frequently Asked Questions — FS-Curtis RNB400
Why Buy the RNB400 from Alamo Equipment & Service?
- Installation available. Buying online gets you the dryer — piping tie-in and drain routing are an extra-charge service. We have the crews to install it and can quote that separately; call (844) 480-6059 for a quote.
- We service it. Refrigerated dryers need periodic filter and drain maintenance to keep dew point performance on spec. Call (844) 480-6059 for maintenance, repairs, or support — and if you ever need warranty work, we register your equipment with the manufacturer and handle the claim directly, so you’re not stuck navigating vendor support on your own.
- We size it with you. 400 SCFM at 232 psig — we’ll confirm this matches your compressor’s actual output and your shop’s air draw before you order.
- Free shipping. Ships free to the 48 contiguous states.
- Expert comparison help. Not sure if the RNB400 or the FS-Curtis RNB500 (500 SCFM) is the better fit? We’ll walk you through it.
A shop buying from a pure e-commerce retailer gets a box. A shop buying from Alamo gets a partner.
Shipping Rates and Delivery Estimates: Shipping is FREE to the 48 contiguous United States.
Shipment Processing Time: All orders are processed within [2–3] business days of receipt, excluding weekends and holidays. Orders are not processed or shipped from Friday at 12 pm CST through Sunday or on holidays. During periods of high order volume, shipments may be delayed by a few days. Customers will be notified via email or phone in the event of significant delays.
See the attached document for FS CURTIS WARRANTY