Graco Inductor Plate, FB300 400 lb Topper-Inductor #204353

SKU: ALMGRA204353
(0)
Regular price $2,330.00
Available to order
Shipping timing is confirmed after order review.

Graco shipping quote

Shipping is quoted by destination before payment. Select your options, then request your freight quote.

Call (817) 865-3707

We will confirm the shipping total before sending a payment link.

Manuals & Resources
Configuration questions before ordering? Call Alamo at (817) 865-3707 — we confirm the fit before the order ships.
Quick Specs
Part Number 204353
Type Inductor plate
Package Fire-Ball 300 50:1 400 lb stationary supply topper-inductor - package 226013
Container class 400 lb (180 kg)
Package column hardware Pump 239888; kit 204467; hose 109150; fittings 100206/156971/205528; elevator 204385; pump support 204461; base 205339
Follower plate / drum cover Not used in the topper-inductor column - empty cells, stated honestly
Air regulator 3/8 in (9.5 mm) 109075 - ordered separately per package footnote
Dimensions / material Not published - omitted

Graco Inductor Plate, FB300 400 lb Topper-Inductor #204353

This plate is built for the shop running (or rebuilding) a Fire-Ball 300 50:1 400 lb topper-inductor grease supply: the high-volume stationary room where a 400 lb drum is lifted by the elevator to the pump mounted on the pump support, and the inductor plate completes the drum-to-pump seal in that raised arrangement. It is a service and a build-out part - if the plate in your topper-inductor install is worn, warped or damaged from drum changes, this is Graco's own replacement piece, matched to the same package column the rest of your hardware came from.

What’s in the Package — Per the Graco Catalog (p.134)

  • The 204353 inductor plate alone — the topper-inductor arrangement piece, not a follower plate; the 226013 column (FB300 50:1 400 lb stationary supply topper-inductor, p.134) carries no follower plate or drum cover at all
  • Its column's hardware: pump 239888, hose and fitting kit 204467 with the 1/4 in x 6 ft hose 109150, fittings 100206/156971/205528, elevator 204385, pump support 204461, base 205339 — all separate part numbers
  • The footnote requires the 3/8 in (9.5 mm) air regulator 109075, ordered separately; the Fire-Ball 425 topper-inductors carry the 205699 plate and the pail topper the 204351 — match the plate to the package

Questions Shops Ask

What does an inductor plate do that a follower plate does not?
It belongs to a different arrangement: in the topper-inductor column the drum is raised to the pump (elevator 204385) with the pump mounted on the pump support (204461) and this plate completing the drum-side of that assembly - whereas follower plates scrape down inside a drum under a cover-mounted pump. The 226013 column carries this plate and no follower plate or cover.

Which packages does it fit?
Graco lists: 1 400 lb topper-inductor package 226013. The Fire-Ball 425 topper-inductor columns use the 205699, and the pail topper uses the 204351 - three different part numbers for three different arrangements.

Does it include the elevator or pump support?
No - those are separate part numbers in the same package column (204385 and 204461), as is the base 205339. This is the plate alone.

Why Buy from Alamo

  • We confirm the configuration before it ships. Pump, kit and container matched to your bulk room — not a guess from a photo.
  • The line is deep with us. Fire-Ball pumps, kits, hoses, covers and hold-downs — the Graco lubrication side is stocked.
  • Freight handled. Heavy items move on a quoted freight profile — call (817) 865-3707 for a quote and lead time before you order.

Fitment & Setup

Compatibility is by package: this is the inductor plate of the Fire-Ball 300 50:1 400 lb topper-inductor package 226013 - the column whose hardware set is elevator 204385, pump support 204461 and base 205339, with the Fire-Ball 300 50:1 pump 239888 above it. The package footnote requires a 3/8 in (9.5 mm) air regulator (109075), ordered separately. If your stationary 400 lb supply is the cover-mount arrangement instead - pump on a cover, follower plate inside the drum, as in the 225016 column - your parts are the follower plate 24F903 and drum cover 200326, not an inductor plate. Confirm which arrangement your room runs before ordering; the two 400 lb columns are different hardware sets.

Your topper arrangement is the pail topper - that column (226012, cart-mounted pail topper, p.132) carries inductor plate 204351 with the pail elevator 203664, a different part number for the 35 lb pail class. Your system is a Fire-Ball 425 topper-inductor - those 400 lb columns (50:1 package 226018 and 75:1 package 244637, pp.139-140) carry inductor plate 205699, not this one. Your supply is cover-mounted - the follower plates (24F903 for this pump family at 400 lb, 223845 in the lube-truck columns) and drum covers are those pieces; an inductor plate has no place in that arrangement.

Need help matching a Graco lubrication part to your setup? Call Alamo Equipment at (817) 865-3707.

Part numbers: 204353

Shipping is quoted by destination before payment. Select your product options and request a freight quote above. We will confirm the freight method and total before sending a payment link.