FS-Curtis RNHI Series
FS-Curtis RNHI Series high-inlet-temperature compressed air dryers — refrigerated dryer configurations engineered for high inlet temperatures typical of compressor discharge air. RNHI Series handles inlet temperatures above standard refrigerated dryer specifications, eliminating the need for an upstream aftercooler in some installations. Suited for direct-from-compressor drying applications and hot-climate installations. Alamo Equipment is an authorized FS-Curtis dealer with sizing consultation and parts availability nationwide.
FS-Curtis RNHI Series FAQs
RNHI is a line of high-inlet-temperature refrigerated air dryers spanning roughly 20 CFM to 125 CFM. They are designed to accept compressed air hotter than a standard refrigerated dryer will tolerate, which makes them the practical option on installations without an effective aftercooler.
When there is no aftercooler between the compressor and the dryer, or when the aftercooler cannot bring discharge temperature down to what a standard dryer requires. This is common on smaller reciprocating installations where an aftercooler was never fitted.
In some smaller installations it can replace one, which is the main reason to choose it. In larger systems an aftercooler is still generally the more efficient approach because removing heat before the dryer reduces the load on the refrigeration circuit.
Match the CFM rating to your compressor's actual delivered flow at working pressure, and confirm the model's rated maximum inlet temperature is above your actual compressor discharge temperature. Both conditions must be satisfied — flow alone is not enough.
Like other refrigerated dryers it targets a dew point suitable for preventing condensation in shop piping at normal indoor temperature. Confirm the rated dew point at your actual inlet temperature, since performance is stated against specific inlet conditions.
The high-inlet refrigerated air dryers collection contains the same RNHI units organized under a different category name. If you are comparing across the site you are looking at the same products in two places, not two different product lines. Either collection will get you to the same models.
Standard refrigerated dryer maintenance: keep the condenser clean, confirm the condensate drain works, and watch for rising dew point. High-inlet units work harder by design, so condenser cleanliness matters more rather than less — a fouled condenser on a high-inlet unit loses performance faster than on a standard dryer.